3.12 Other Cable Line Material Examination

3.12.1 Size and allowable deviation of cement bases,chucks and anchor plates shall be those set in Table 3.12.1.

Table 3.12.1 Dimension and allowable deviation of cement base,chuck and anchor plate

img

3.12.2 Plastic subducts shall meet the following requirements:

1 Material and specification of subducts shall comply with design requirements.

2 Surface of subduct shall be smooth without any deformation.Its color,aperture and wall thickness shall meet the design requirements.